Heated and Chilled Post Cap Ceilings
These well-directed ceiling constructions with Post Cap profiles can be adapted to every building shape and offer versatile scope for design. All avenues of ceiling design are open thanks to freely selectable distances of Post Cap profiles and our range of diverse ceilings with Post Caps and Cross Noggins.
A special visual variant are radially installed Post Caps combined with trapezoidal metal ceiling panels. Even longitudinally sound reduced Post Cap ceilings allow you to install partition walls to the Post Cap profiles. Thus, you can flexibly change your room layout and use the free ceiling void for installations.
Plafotherm® B 100 - Linear
Construction: | Linear C-Post Caps, standard width 100, 125, 150, 200 mm |
Suspension: | Nonius suspension, threaded rod |
Ceiling panels: | |
Type 1: | Lay-In |
Type 2: | Lay-In with Hook-On edge |
Type 3: | Lay-In with Hook-On notch |
Type 4: | Lay-In, Swing-Down on longitudinal side |
Type 6: | Lay-In, Swing-Down on short side |
Max. dimensions depending on the execution: | |
Length: | Up to 2950 mm |
Width: | Up to 1250 mm |
Characteristic: | Lighting technology can be integrated in the Post Cap, Swing-Down function by means of high-grade hinging and locking technology |
Plafotherm® B 100 SD - Linear
Construction: | Linear C-Post Caps, standard width 100 mm |
Suspension: | Nonius suspension, threaded rod |
Sandwich ceiling panels: | |
Type 1: | Lay-In |
Type 2: | Lay-In with Hook-On edge |
Max. dimensions depending on the execution: | |
Length: | Up to 1800 mm |
Width: | Up to 500 mm |
Characteristic: | Longitudinally sound reduced |
Value: | Dn,f,w = 43 dB without mineral wool and without isolation Dn,f,w = 48 dB with mineral wool and without isolation Dn,f,w = 62 dB with mineral wool and with isolation |
Fixing of partition walls: | Directly screwed to the C-Post Cap |
Plafotherm® B 110 - Cross Noggins
Construction: | Post Cap ceiling with C-Post Caps and Cross Noggins, standard width 100, 125, 150, 200 mm |
Suspension: | Nonius suspension, threaded rod |
Ceiling panels: | |
Type 1: | Lay-In |
Type 2: | Lay-In with Hook-On edge |
Type 3: | Lay-In with Hook-On notch |
Type 4: | Lay-In, Swing-Down on longitudinal side |
Type 6: | Lay-In, Swing-Down on short side |
Max. dimensions depending on the execution: | |
Length: | Up to 2950 mm |
Width: | Up to 1250 mm |
Characteristic: | Lighting technology can be integrated in the Post Cap, Swing-Down function by means of high-grade hinging and locking technology |
Plafotherm® B 137 SD - Linear, concealed Post Cap
Construction: | linear Post Caps with centre groove, concealed Post Cap |
Suspension: | bracket suspension |
Sandwich Ceiling panels: | |
Type 1: | Lay-In with locking technology |
Max. dimensions depending on the exectuion: | |
Length: | Up to 1500 mm |
Width: | Up to 1250 mm |
Characteristic: | longitudinally sound reduced, Swing-Down function by means of locking technology and installation ropes |
Value: | Dn,f,w = 50 dB without isolation |
Fixing of partition walls: | Directly fastened to the groove of the C-Post Cap |