Doors for Wet Rooms and Moisture-prone Areas
Moisture-protection.
A high level of air humidity places particular demands on the materials that can be used in a building. If these are not met, this can very quickly result in serious damage to the structure of your building.
Lindner wet room and moisture-proof doors are especially suitable for toilet and washroom blocks, kitchens, hotel saunas, hospitals or windowless bathrooms. The doors can be used in rooms with high levels of air humidity (up to 100%) or where they might come into contact with spray, condensation or dripping water.
For doors to your wet-rooms or moisture-prone areas Lindner would recommend that you select surfaces which are hygienic and easy to clean. With Lindner solutions, all your doors will always remain dry!
Properties:
- Tested to comply with RAL GZ 426
- Tested to comply with RAL RG 426
- Architraves and wall fascia panels for use in moisture-prone areas are also available with our special lacquering process.
Wooden Doors - Single Leaf
Object Door Type "A"
Door leaf: | 41 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | Radiation protection | |
Options on demand: | Sound insulation |
Object Door Type "B"
Door leaf: | 41 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | Radiation protection | |
Options on demand: | Sound insulation |
Object Door Type "C"
Door leaf: | 49 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to DIN EN ISO 140-03: up to 42 dB Rw (= laboratory value) | |
Options: | Burglary resistance, radiation protection, moisture resistance | |
Options on demand: | Sound insulation |
Object Door Type "D"
Door leaf: | 68 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | Burglary resistance, radiation protection | |
Options on demand: | Sound insulation |
Fire Door Type "H"
Door leaf: | 49 mm with laminated intermediate layer and strenghteners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | Burglary resistance, radiation protection | |
Options on demand: | Smoke control, sound insulation |
Fire Door Type "I"
Door leaf: | 68 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | Burglary resistance, radiation protection | |
Options on demand: | Fire protection, smoke control, sound insulation |
Fire Door "O"
Door leaf: | 75 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room | |
Options: | Burglary resistance | |
Options on demand: | Fire protection, smoke control, sound insulation |
Wooden Doors - Double Leaf
Object Door Type "E"
Door leaf: | 49 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | Radiation protection | |
Options on demand: | Sound insulation |
Object Door Type "F"
Door leaf: | 68 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | Radiation protection | |
Options on demand: | Sound insulation |
Fire Door Type "L"
Door leaf: | 49 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | Radiation protection | |
Options on demand: | Fire protection, smoke control, sound insulation |
Fire Door Type "M"
Door leaf: | 68 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room, according to RAL-RG 426: Wet room | |
Options: | radiation protection | |
Options on demand: | Fire protection, smoke control, sound insulation |
Fire Door Type "P"
Door leaf: | 75 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Moisture resistance: | According to RAL-GZ 426: Moisture room | |
Options: | Burglary resistance | |
Options on demand: | Fire protection, smoke control, sound insulation |