Fire protection doors

Simply safe.

Fire protection can not only save lives but can also protect your building from greater damage. Efficient fire-proof elements prevent the rapid spread of fire and thus provide vital time for people to escape.

As a manufacturer of fire-proof doors, Lindner can provide the most diverse solutions, all manufactured to first-class quality - tailored to your precise needs.

The advantages of Lindner fire-proof doors:

  • Optimum price-performance ratio
  • T30 Fire-proof elements up to Rw = 47 dB  (= laboratory value)
  • T90 Fire-proof elements up to Rw = 42 dB (= laboratory value)
  • Doors with light recesses up to Rw = 43 dB (= laboratory value)
  • Flush-mounted fire-proof glazing (optional)
  • Can be combined with fixed glazing
  • Can be combined with other protective functions
  • Elements up to 4 m high and 4.5 m wide tested
  • Highly durable PU edging (solid coloured and wet room-tested)

Wooden Doors - Single Leaf

Fire Door Type "H"

Door leaf:49 mm with laminated intermediate layer and strengtheners of oriented strand board 
Fire protection:  According to DIN EN 1634: T30 / EI2 30 C5
Options:Smoke control, sound insulation, burglary resistance, radiation protection, moisture resistance

Fire Door Type "H-MHR"

Door leaf:Solid wood frame door leaf 49 mm 
Fire protection:  According to DIN EN 1634: T30 / EI2 30 C5
Options:Smoke control, sound insulation, burglary resistance

Fire Door Type "I"

Door leaf:68 mm with laminated intermediate layer and strengtheners of oriented strand board 
Fire protection:  According to DIN EN 1634: T30 / EI2 30 C5
Options:Smoke control, sound insulation, burglary resistance, radiation protection, moisture resistance

Fire Door Type "I-MHR"

Door leaf:Solid wood door frame leaf 68 mm  
Fire protection:  According to DIN EN 1634: T30 / EI2 30 C5
Options:Smoke control, sound insulation, burglary resistance

Fire Door Type "O"

Door leaf:75 mm with laminated intermediate layer and strengtheners of oriented strand board 
Fire protection:  According to DIN EN 1634: T90 / EI2 90 C5
Options:Smoke control on demand, sound insulation, burglary resistance, moisture resistance

Wooden Doors - Double Leaf

Fire Door Type "L"

Door leaf:49 mm with laminated intermediate layer and strengtheners of oriented strand board 
Fire protection:  According to DIN EN 1634: T30 / EI2 30 C5
Options:Smoke control, sound insulation, radiation protection, moisture resistance

Fire Door Type "L-MHR"

Door leaf:Solid wood door frame leaf 49 mm  
Fire protection:  According to DIN EN 1634: T30 / EI2 30 C5
Options:Smoke control, sound insulation

Fire Door Type "M"

Door leaf:68 mm with laminated intermediate layer and strengtheners of oriented strand board 
Fire protection:  According to DIN EN 1634: T30 / EI2 30 C5
Options:Smoke control, sound insulation, radiation protection, moisture resistance

Fire Door Type "M-MHR"

Door leaf:Solid wood door frame leaf 68 mm  
Fire protection:  According to DIN EN 1634: T30 / EI2 30 C5
Options:Smoke control, sound insulation

Fire Door Type "P"

Door leaf:75 mm with laminated intermediate layer and strengtheners of oriented strand board 
Fire protection:  According to DIN EN 1634: T90 / EI2 90 C5
Options:Smoke control on demand, sound insulation on demand, burglary resistance, moisture resistance

Niche Doors

Niche Door Type "M / I"

Door leaf: 68 mm + 16 mm doubling
Fire protection:   According to DIN EN 1634: T30
Options: Smoke control, sound insulation

Aluminium Frame Doors - Single and double leaf

Fire Door Type "ATB - ADS 80 FR 30"

Door leaf:80 mm 
Fire protection: According to DIN 4102: T30
According to DIN EN 1634: EI30
Options:Combination with Lindner partition systems, smoke control, sound insulation

Fire Door Type " ADS 80 FR 30"

Door leaf:80 mm 
Fire protection: According to DIN 4102: T30
According to DIN EN 1634: EI30
Options:Smoke control, sound insulation, burglary resistance

Fire Door Type "ATB – ADS 80 FR 60"

Door leaf:80 mm 
Fire protection: According to DIN 4102: T60
According to DIN EN 1634: EI60
Options:Combination with Lindner partition systems,  sound insulation, smoke control

Fire Door Type "ADS 80 FR 60"

Door leaf:80 mm 
Fire protection: According to DIN 4102: T60
According to DIN EN 1634: EI30
Options:Sound insulation, smoke control, burglary resistance

Fire Door Type "Firestop"

Door leaf:105 mm 
Fire protection: According to DIN 4102: T90
Options:Smoke control

Glass Door Leafs - Single and double leaf

Fire door type “GTB - ADS 80 FR 30"

Door leaf: 100 mm
Fire protection:   According to DIN 4102: T30 According to DIN EN 1634: EI30
Options:Combination with Lindner partition systems, smoke control, sound insulation