Post Cap Ceilings
These well-directed ceiling constructions with Post Cap profiles can be adapted to every building shape and offer versatile scope for design. All avenues of ceiling design are open thanks to freely selectable distances of Post Cap profiles and our range of diverse ceilings with Post Caps and Cross Noggins.
A special visual variant are radially installed Post Caps combined with trapezoidal metal ceiling panels. Post Cap ceilings allow you to install partition walls to the Post Cap profiles. Thus, you can flexibly change your room layout.
LMD-B 100 - Linear
Construction: | Linear C-Post Caps, standard width 100, 125, 150, 200 mm |
Suspension: | Nonius suspension, threaded rod |
Ceiling panels: | |
Type 1: | Lay-In |
Type 2: | Lay-In with Hook-On edge |
Type 3: | Lay-In with Hook-On notch |
Type 4: | Lay-In, Swing-Down on longitudinal side |
Type 6: | Lay-In, Swing-Down on short side |
Max. dimensions depending on the execution: | |
Length: | Up to 3300 mm (Type 1-3) resp. up to 3000 mm (Type 4-6) |
Width: | Up to 1250 mm |
Characteristic: | Lighting technology can be integrated in the Post Cap, Swing-Down function by means of high-grade hinging and locking technology |
LMD-B 100 SD - Linear
Construction: | Linear C-Post Caps, standard width 100 mm |
Suspension: | Nonius suspension, threaded rod |
Sandwich ceiling panels: | |
Type 1: | Lay-In |
Type 2: | Lay-In with Hook-On edge |
Max. dimensions depending on the execution: | |
Length: | Up to 1800 mm |
Width: | Up to 625 mm |
Characteristic: | Longitudinally sound reduced |
Value: | Dn,f,w = 49 dB without isolation |
Fixing of partition walls: | Directly screwed to the C-Post Cap |
LMD-B 110 - Cross Noggins
Construction: | Post Cap ceiling with C-Post Caps and Cross Noggins, standard width 100, 125, 150, 200 mm |
Suspension: | Nonius suspension, threaded rod |
Ceiling panels: | |
Type 1: | Lay-In |
Type 2: | Lay-In with Hook-On edge |
Type 3: | Lay-In with Hook-On notch |
Type 4: | Lay-In, Swing-Down on longitudinal side |
Type 6: | Lay-In, Swing-Down on short side |
Max. dimensions depending on the execution: | |
Length: | Up to 3300 mm (Type 1-3) resp. up to 3000 mm (Type 4-6) |
Width: | Up to 1250 mm |
Characteristic: | Lighting technology can be integrated in the Post Cap, Swing-Down function by means of high-grade hinging and locking technology |
Contact
Ceiling Systems
Phone +49 8723 20-3679
» Contact Form
Downloads
Tender Texts
Please find Tender Texts and DIN/VOB specifications at:
» www.ausschreiben.de
For NBS specifications please visit:
» www.theNBS.com (Login required)
or » www.ribaproductselector.com
For more information please contact our product management.