Fire protection doors
Simply safe.
Fire protection can not only save lives but can also protect your building from greater damage. Efficient fire-proof elements prevent the rapid spread of fire and thus provide vital time for people to escape.
As a manufacturer of fire-proof doors, Lindner can provide the most diverse solutions, all manufactured to first-class quality - tailored to your precise needs.
The advantages of Lindner fire-proof doors:
- Optimum price-performance ratio
- T30 Fire-proof elements up to Rw = 47 dB (= laboratory value)
- T90 Fire-proof elements up to Rw = 42 dB (= laboratory value)
- Doors with light recesses up to Rw = 43 dB (= laboratory value)
- Flush-mounted fire-proof glazing (optional)
- Can be combined with fixed glazing
- Can be combined with other protective functions
- Elements up to 4 m high and 4.5 m wide tested
- Highly durable PU edging (solid coloured and wet room-tested)
Wooden Doors - Single Leaf
Fire Door Type "H"
Door leaf: | 49 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Fire protection: | According to DIN EN 1634: T30 / EI2 30 C5 | |
Options: | Smoke control, sound insulation, burglary resistance, radiation protection, moisture resistance |
Fire Door Type "H-MHR"
Door leaf: | Solid wood frame door leaf 49 mm | |
Fire protection: | According to DIN EN 1634: T30 / EI2 30 C5 | |
Options: | Smoke control, sound insulation, burglary resistance |
Fire Door Type "I"
Door leaf: | 68 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Fire protection: | According to DIN EN 1634: T30 / EI2 30 C5 | |
Options: | Smoke control, sound insulation, burglary resistance, radiation protection, moisture resistance |
Fire Door Type "I-MHR"
Door leaf: | Solid wood door frame leaf 68 mm | |
Fire protection: | According to DIN EN 1634: T30 / EI2 30 C5 | |
Options: | Smoke control, sound insulation, burglary resistance |
Fire Door Type "O"
Door leaf: | 75 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Fire protection: | According to DIN EN 1634: T90 / EI2 90 C5 | |
Options: | Smoke control on demand, sound insulation, burglary resistance, moisture resistance |
Wooden Doors - Double Leaf
Fire Door Type "L"
Door leaf: | 49 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Fire protection: | According to DIN EN 1634: T30 / EI2 30 C5 | |
Options: | Smoke control, sound insulation, radiation protection, moisture resistance |
Fire Door Type "L-MHR"
Door leaf: | Solid wood door frame leaf 49 mm | |
Fire protection: | According to DIN EN 1634: T30 / EI2 30 C5 | |
Options: | Smoke control, sound insulation |
Fire Door Type "M"
Door leaf: | 68 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Fire protection: | According to DIN EN 1634: T30 / EI2 30 C5 | |
Options: | Smoke control, sound insulation, radiation protection, moisture resistance |
Fire Door Type "M-MHR"
Door leaf: | Solid wood door frame leaf 68 mm | |
Fire protection: | According to DIN EN 1634: T30 / EI2 30 C5 | |
Options: | Smoke control, sound insulation |
Fire Door Type "P"
Door leaf: | 75 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Fire protection: | According to DIN EN 1634: T90 / EI2 90 C5 | |
Options: | Smoke control on demand, sound insulation on demand, burglary resistance, moisture resistance |
Niche Doors
Niche Door Type "M / I"
Door leaf: | 68 mm + 16 mm doubling |
Fire protection: | According to DIN EN 1634: T30 |
Options: | Smoke control, sound insulation |
Aluminium Frame Doors - Single and double leaf
Fire Door Type "ATB - ADS 80 FR 30"
Door leaf: | 80 mm | |
Fire protection: | According to DIN 4102: T30 According to DIN EN 1634: EI30 | |
Options: | Combination with Lindner partition systems, smoke control, sound insulation |
Fire Door Type " ADS 80 FR 30"
Door leaf: | 80 mm | |
Fire protection: | According to DIN 4102: T30 According to DIN EN 1634: EI30 | |
Options: | Smoke control, sound insulation, burglary resistance |
Fire Door Type "ATB – ADS 80 FR 60"
Door leaf: | 80 mm | |
Fire protection: | According to DIN 4102: T60 According to DIN EN 1634: EI60 | |
Options: | Combination with Lindner partition systems, sound insulation, smoke control |
Fire Door Type "ADS 80 FR 60"
Door leaf: | 80 mm | |
Fire protection: | According to DIN 4102: T60 According to DIN EN 1634: EI30 | |
Options: | Sound insulation, smoke control, burglary resistance |
Fire Door Type "Firestop"
Door leaf: | 105 mm | |
Fire protection: | According to DIN 4102: T90 | |
Options: | Smoke control |
Glass Door Leafs - Single and double leaf
Fire door type “GTB - ADS 80 FR 30"
Door leaf: | 100 mm |
Fire protection: | According to DIN 4102: T30 According to DIN EN 1634: EI30 |
Options: | Combination with Lindner partition systems, smoke control, sound insulation |