Fire resistance class F90-A/AB
Our F90 Suspended Fireproof Ceilings withstand the temperatures of fire for 90 minutes and are tested from above (Type 3/5/8). The fire-resistant ceilings are tested according to DIN 4102-2 and stated in a general building regulations test certificate. The different executions are either available with the classification "F90-A" or "F90-AB".
Our systems can prevent the spread of fire and offer decisive minutes in case of emergency. The fire-resistant ceiling systems are very user-friendly and their detail solutions are sophisticated.
Type 3 - Hook-On
Construction: | Concealed Hook-On construction |
Ceiling panels: | |
Type 3: | With mineral wool |
Max. dimensions depending on the execution: | |
Length: | Up to 2500 mm |
Width. | Up to 397 mm |
Characteristic: | Removable without the need for any tools |
» Downloads |
Type 5 - Drop-Slide
Construction: | Drop-Slide Hook-On profile |
Ceiling panels: | |
Type 5: | With mineral wool |
Max. dimensions depending on the execution: | |
Length: | Up to 2500 mm |
Width. | Up to 397 mm |
Characteristic: | Removable without the need for any tools, patented Drop-Slide function; building traffic is not affected by vertically dangling panels when opened for maintenance purposes |
» Downloads |
Type 8 - Swing-Down/Slide
Construction: | Concealed Hook-On construction |
Ceiling panels: | |
Type 8: | With mineral wool |
Max. dimensions depending on the execution: | |
Length: | Up to 2500 mm |
Width. | Up to 397 mm |
Characteristic: | Removable without the need for any tools |
» Downloads |
Fixtures
Ventilation systems
The following ventilation systems can be integrated in suspended fireproof ceilings:
Wildeboer:
- BV90
Contact
Ceiling Systems
Phone +49 8723 20-3679
» Contact Form
Downloads
Tender Texts
Please find Tender Texts and DIN/VOB specifications at:
» www.ausschreiben.de
For NBS specifications please visit:
» www.theNBS.com (Login required)
or » www.ribaproductselector.com
For more information please contact our product management.