Smoke Control Doors
Clear conditions.
In the event of a fire, emergency escape routes and information signs have to continue to be easily visible despite the smoke. Lindner smoke-proof doors prevent the spread of smoke, in compliance with DIN 18095, and provide for clear emergency escape routes.
The following are available:
- Single- and double-leaf door elements
- Light recesses - fan lights
- Doors up to 3 m in height with a top panel up to 4 m
- Single-leaf doors up to 1500 mm in width
- Double-leaf doors up to 3000 mm in width
- Can be combined with sound insulation and burglary protection
Wooden Doors - Single Leaf
Fire Door Type "H"
Door leaf: | 49 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Smoke control: | According to DIN 18095 | |
Options: | Fire protection, sound insulation, burglary resistance, radiation protection |
Fire Door Type "H-MHR"
Door leaf: | Solid wood frame door leaf 49 mm | |
Smoke control: | According to DIN 18095 | |
Options: | Fire protection, sound insulation, burglary resistance |
Fire Door Type "I"
Door leaf: | 68 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Smoke control: | According to DIN 18095 | |
Options: | Fire protection, sound insulation, burglary resistance, radiation protection |
Fire Door Type "I-MHR"
Door leaf: | Solid wood door frame leaf 68 mm | |
Smoke control: | According to DIN 18095 | |
Options: | Fire protection, sound insulation, burglary resistance |
Fire Door Type "O"
Door leaf: | 75 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Smoke control: | According to DIN 18095: on demand | |
Options: | Fire protection, sound insulation, burglary resistance |
Wooden Doors - Double Leaf
Fire Door Type "L"
Door leaf: | 49 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Smoke control: | According to DIN 18095 | |
Options: | Fire protection, sound insulation, radiation protection |
Fire Door Type "L-MHR"
Door leaf: | Solid wood door frame leaf 49 mm | |
Smoke control: | According to DIN 18095 | |
Options: | Fire protection, sound insulation |
Fire Door Type "M"
Door leaf: | 68 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Smoke control: | According to DIN 18095 | |
Options: | Fire protection, sound insulation, radiation protection |
Fire Door Type "M-MHR"
Door leaf: | Solid wood door frame leaf 68 mm | |
Smoke control: | According to DIN 18095 | |
Options: | Fire protection, sound insulation |
Fire Door Type "P"
Door leaf: | 75 mm with laminated intermediate layer and strengtheners of oriented strand board | |
Smoke control: | According to DIN 18095: on demand | |
Options: | Fire protection, sound insulation on demand, burglary resistance |
Niche Doors
Niche Door Type "D / F"
Door leaf: | 68 mm + 16 mm doubling |
Smoke control: | According to DIN 18095 |
Options: | Sound insulation |
Niche Door Type "M / I"
Door leaf: | 68 mm + 16 mm doubling |
Smoke control: | According to DIN 18095 |
Options: | Fire protection, sound insulation |
Aluminium Frame Doors - Single and double leaf
Smoke Control Door Type "ADS 65 NI SP"
Door leaf: | 65 mm |
Smoke control: | According to DIN 18095 / EN 1634-3 |
Options: | Burglary resistance, sound insulation |